Tenant Improvement Standards Print E-mail

1) Flooring and Base

Carpet: 28 oz Level Broadloom with unity backing.
VCT: 12 x 12 Armstrong Series.
Base: 4” rubber top set with toe. 

2) Walls 

5/8” type gyp board over 3 5/8 x 25 gauge metal studs at 24” o.c. to 6” above ceiling. Smooth or light orange peel textured finish. 

3) Doors 

Tenant Entry: 3’ x 7’ x 1-3/4” Plastic Laminate Faced Solid Core Wood.
Tenant Interior: 3’ x 7’ x 1-3/4” solid core. Plain cut. Birch. Stain Grade. 

4) Door Frame and Hardware 

Frame: Knock-Down Hollow Metal, Paint Finish. 

Hardware: Schlage “D” Series Lever Sets with “Sparta” style levers in 626 Satin Plated Finish (US26D) 

5) Ceiling 

2 x 4 acoustical Armstrong Second Look II. 

6) Lighting 

Lithonia 18 cell 3 tube parabolic with electronic ballast and T-8 lamps. 1 Fixture per every 90 usable square feet. Dual level manual switching 

Ceiling mounted illuminated exit sign w/ battery backup per 2001 California Building Code. 

7) HVAC 

Variable air volume terminal with hot water re-heat coils in each suite. 

Flex ducting and hydronic piping from mechanical duct chase to supply/return grilles.
Thermostats & control system wiring to roof top air handler. 

Supply and return grilles: 2 x 2 flat lay-in with integral deflector. 

8) Exterior Glazing Perimeter Blinds 

Vertical perforated blinds